Sma Inverters String Sizing Tool

Design Tools. One of the most. Seems the SMA TL Inverters are not sizing correctly with the SunPower 327s. At this time the REA string sizing tool has no.

  1. Sma String Sizer Tool
  2. Sma Inverters String Sizing

Phase Phase is used to describe the two main types of alternating current (AC) electric power produced by a utility, generator or UPS system. Single-phase power includes a single AC waveform, making single-phase equipment ideal for lower power density applications with per-rack power consumption levels up to approximately 2.8kVA (120V), 5kVA (208V) or 7.4kVA (230V). Three-phase power includes 3 AC waveforms, making 3-phase equipment better suited for intermediate and high-capacity applications with per-rack power consumption levels that surpass the practical energy limits of single-phase equipment. PDU Type Basic PDUs All PDUs including Basic PDUs provide reliable rack-mount power distribution for data centers, server rooms, and network wiring closets.

Metered PDUs Metered PDUs monitor load levels to avoid potential overloads via a LCD display. Monitored PDUs Monitored PDUs remotely monitor voltage, frequency, and load levels via a built-in network connection.

Sma Inverters String Sizing Tool

Switched PDUs Switched PDUs can securely control individual outlets remotely to enable the rebooting of unresponsive equipment to minimize downtime. Auto Transfer Switch (ATS) PDUs ATS PDUs provide redundant power to connected equipment with separate primary and secondary power sources. Hot-Swap PDUs Hot-Swap PDUs have dual input power cables to enable live-replacement of select UPS systems with no power interruption to connected equipment.

For many new to photovoltaic system design, determining the maximum number of modules per series string can seem straight forward, right? Simply divide the inverter’s maximum system voltage rating by the open circuit voltage (Voc) of the module used and you’re good. Well, that does get you in the ballpark, however you could be at risk of over-sizing or under-sizing the number of modules in a string depending on where you are located in the world. So in order to spot check ourselves we can employ a couple of simple calculations to ensure that we do not encounter these set of problems. There are a plethora of string sizing tools out there. Some are from the inverter manufactures and others are intricate home-brew type tools.

Sma String Sizer Tool

These can be great to do the double checking for you, but often the module that we are using is too new, obsolete or simply not listed in the database of the tool that we are using. Not to worry, these calculations are easy enough to do by hand or to input into a spreadsheet. Let’s just dive in shall we? I’ll set up a fictitious scenario with all the elements that we would need to be able to complete the calculations, including a module that is new enough that not many online string tools have it in their databases. PV Module: The values that we need to collect from the data sheet is the Voc, cell temperature used for standard test conditions (STC), temperature coefficient of Voc, maximum power point voltage (Vmp), and temperature coefficient of Vmp Voc: 45.9, ºC @ STC: 25, TCVoc: -0.304, Vmpp: 36.7, TC Pmpp: -0.43 Inverter Model: The two most important values to collect are the maximum DC input voltage and the start or strike voltage of the inverter. 600 Vmax, 150 Vstart Now we need to dig up environmental data of the location. There are two fantastic resources to use here and all you need to do is enter the zip-code of the location to find the weather data nearest to your location.

Sma Inverters String Sizing

My next step is to go to or for the ASRAE data for Memphis, TN 38116. I recommend the latter for areas outside North America for our international friends. The important information to collect form either of these two sources are going to be record low, the 2% annual design dry bulb temperature and the expected rise in cell temperature due to mounting method (more on that ). Let’s start by calculating the minimum number of modules that we should have in a series string. This is a three part calculation. Vmin = (Vmp + ((THigh + TRise - TStc) x (VmpCoef x Vmp/100))) Vmin = 36.7V + ((35ºC + 32ºC - 25ºC) x (-0.43 x 36.7/100))) Vmin = 36.7 + (42 x -0.158) Vmin = 30.064 V Next we should factor in system loses (de-rate factor). We forgo this calculation for the purpose of simplifying this exercise and assume our derate factor to be 12% or 0.88 Vmin = 30.064 x 0.88 Vmin = 26.46 We can now take our result from the above calculations to determine the bare minimum number of modules we can expect to have in our system by dividing our DC start (strike) voltage by our Vmin.

150 / 26.46 = 5.67 rounded up to the nearest whole number. The minimum number of modules in series can be a low as 6. Now we can calculate the maximum number of modules that we can have in our system by doing a very similar type of calculation. Vmax = Voc + ((TLow - TStc) x (VocCoef x Voc/100)) Vmax = 45.9 + ((-12ºC - 25ºC) x (-0.304 x 45.9/100)) Vmax = 45.9 + (37 x 0.14) Vmax = 51.08 Now, divide our result by the maximum DC system voltage of the chosen inverter and round down to the nearest whole number. 600 / 51.08 = 11.74 The maximum number of modules in series can be as much as 11. Now we have all the parameters that we need to design a system which will not go over the maximum input voltage of the inverter at record lows and will meet the minimum start up voltage of the inverter where cell temps are at their highest. I like to keep a database of inverters and modules in a spreadsheet and populate the data needed in these calculations to save time, but you can simply plug these values into the formulas themselves if you are not too savvy with spreadsheets.